Connecting the mains cable

General

If no mains cable is connected, a mains cable that is suitable for the connection voltage
must be fitted before commissioning.
A universal strain-relief device for cable diameters from 12 - 30 mm (0.47 - 1.18 in.) is fitted
to the power source.
Strain-relief devices for other cable cross-sections must be designed accordingly.
Stipulated mains
Power source
cables
TPS 320i /nc
TPS 320i /MV/nc
TPS 320i /600V/nc **
TPS 400i /nc
TPS 400i /MV/nc
TPS 400i /600V/nc **
TPS 500i /nc
TPS 500i /MV/nc
TPS 500i /600V/nc **
TPS 600i /nc
TPS 600i /600V/nc **
*
**
AWG = American wire gauge
Mains voltage
3 x 400 V
3 x 460 V
3 x 230 V
3 x 460 V
3 x 575 V
3 x 400 V
3 x 460 V
3 x 230 V
3 x 460 V
3 x 575 V
3 x 400 V
3 x 460 V
3 x 230 V
3 x 460 V
3 x 575 V
3 x 400 V
3 x 460 V
3 x 575 V
Cable type for USA / Canada: Extra-hard usage
Power source without CE mark; not available in Europe
Cable cross-section
USA / Canada *
Europe
AWG 12
4 G 2.5
AWG 14
4 G 2.5
AWG 10
4 G 4
AWG 14
4 G 2.5
AWG 14
-
AWG 10
4 G 4
AWG 12
4 G 4
AWG 6
4 G 6
AWG 10
4 G 4
AWG 12
-
AWG 8
4 G 4
AWG 10
4 G 4
AWG 6
4 G 10
AWG 10
4 G 4
AWG 10
-
AWG 6
4 G 10
AWG 6
4 G 10
AWG 6
-