Process Parameters, General; Process Parameters For Start Of Welding/End Of Welding - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

Process parameters, General

Process parame-
The following process parameters can be set and displayed for the start and end of weld-
ters for start of
ing:
welding/end of
welding
Starting current
for setting the starting current for MIG/MAG welding (e.g. aluminium welding start-up)
Unit
Setting range
Factory setting
Start arc length correction
For correcting the arc length at the start of welding
Unit
Setting range
Factory setting
-
0
+
Starting current time
for setting the length of time the starting current is to be active
Unit
Setting range
Factory setting
Slope 1
for setting the time during which the starting current is decreased or increased to the
welding current
Unit
Setting range
Factory setting
Slope 2
for setting the time during which the welding current is decreased or increased to the final
current.
Unit
Setting range
Factory setting
100
% (of welding current)
0 - 200
135
% (of welding voltage)
-10.0 - +10.0
0.0
shorter arc length
neutral arc length
longer arc length
s
off / 0.1 - 10.0
off
s
0.0 - 9.9
1.0
s
0.0 - 9.9
1.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tps 600iTps 400i lsc advTps 400iTps 500i

Table of Contents