Welding Parameters For Manual Metal Arc Welding - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

8
The value of the welding parameter is displayed as a horizontal scale:
The value of the selected parameter can now be changed.
9
10
11
Welding parame-
The following welding parameters for MMA welding can be set and displayed by pressing
ters for manual
the "Welding" button:
metal arc welding
Main current
Unit
Setting range
Before the start of welding, the device automatically displays a standard value based on
the programmed parameters. During welding, the actual value is displayed.
Starting current
for setting a starting current value in the range 0 - 200% of the set welding current in order
to avoid slag inclusions or incomplete fusion.
The starting current depends on the electrode type.
Unit
Setting range
Factory setting
The starting current is active for the starting current time set under the process parame-
ters.
Dynamic
Unit
Setting range
Factory setting
0
100
98
Press the adjusting dial to change the welding parameter
Turn the adjusting dial and change the parameter
Adjust the process parameters accordingly to make user- or application-specific set-
tings on the welding system
Start welding
to influence the short-circuiting dynamic at the instant of droplet transfer
9
A
depends on the power source available
%
0 - 200
150
-
0 - 100
20
Soft, low-spatter arc
Harder, more stable arc