TPS 500i
Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Mains fuse protection
Mains voltage tolerance
Mains frequency
Cos phi (1)
Max. permissible mains impedance Z
Recommended earth-leakage circuit breaker
Welding current range (I
MIG/MAG
TIG
Rod electrode
Welding current at
Output voltage range according to standard characteristic (U
MIG/MAG
TIG
Rod electrode
Open circuit voltage (U
Degree of protection
Type of cooling
Overvoltage category
Pollution level according to IEC60664
EMC device class
Safety symbols
Dimensions l x w x h
Weight
Max. noise emission (LWA)
1)
2)
214
)
1
)
1max
)
2
10 min/40 °C (104 °F)
peak / U
0
Interface to a 230/400 V, 50 Hz public grid
An emission class A device is not designed for use in residential areas supplied
with power from a public low-voltage grid.
The electromagnetic compatibility can be influenced by conducted or radiated ra-
dio frequencies.
)
1eff
1)
on PCC
max
r.m.s)
0
3 x
400 V
23.7 A
37.5 A
35 A slow-blow
+/- 15%
50/60 Hz
0.99
49 mOhm
Type B
3 - 500 A
3 - 500 A
10 - 500 A
40%
60%
100%
500 A
430 A
360 A
)
2
14.2 - 39.0 V
10.1 - 30.0 V
20.4 - 40.0 V
71 V
IP 23
S, CE
706 x 300 x 510 mm
27.8 x 11.8 x 20.1 in.
38 kg
83.8 lb.
74 dB (A)
AF
III
3
2)
A