Technical Data; Explanation Of The Term "Duty Cycle; Special Voltages - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

Technical data

Explanation of
Duty cycle (D.C.) is the proportion of time in a 10-minute cycle at which the device may be
the term "duty cy-
operated at its rated output without overheating.
cle"
Example: Welding at 150 A at 60% D.C.
-
-
-
150 A
If the device is to be continuously operated without stopping:
1
2

Special voltages

For devices designed for special voltages, the technical data on the rating plate applies.
For all machines with a permitted mains voltage of up to 460 V: The standard mains plug
allows the user to operate with a mains voltage of up to 400 V. For mains voltages up to
460 V fit a mains plug permitted for such use or install the mains supply directly.
NOTE! The D.C. values specified on the rating plate are based on an ambient
temperature of 40°C. If the ambient temperature is higher, either the D.C. or out-
put must be reduced accordingly.
Welding phase = 60% of 10 minutes = 6 minutes
Cooling phase = remaining time = 4 minutes
After the cooling phase, the cycle begins anew.
60 %
6 Min.
0 A
0 Min.
look in the technical data for a D.C. value of 100% for the reigning ambient tempera-
ture.
Reduce the output or amperage in line with this value so that the device can remain in
use without observing a cooling phase.
4 Min.
6 Min.
10 Min.
201

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tps 600iTps 400i lsc advTps 400iTps 500i

Table of Contents