Retrieving System Data - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

Retrieving sys-
tem data
1
2
3
The current system data is displayed.
1
Select "Defaults"
Select "View"
Select "System data"
Arc power from real-time values in kW
IP delivers the correct mean value of the arc power due to the high sam-
ple measuring rate during non-continuous welding processes.
If the welding speed is known, the electrical energy input can be calcu-
lated:
E = IP / vs
E
Electrical energy input in kJ/cm
IP
Arc power in kW
vs
Welding speed in cm/s
3
2
137