Process parameters, Job

Optimising job
The following process parameters can be set for the job:
process parame-
ters
Job parameter
Torch mode
For setting the welding mode
Unit
Setting range
Wire speed
For adjusting the wire speed
Unit
Setting range
Arc length correction
For correcting the arc length
Unit
Setting range
-
0
+
Pulse/Arc-force dynamic correction
For correcting the pulse energy during pulsed arc welding
Setting range
-
0
+
For influencing the short-circuiting dynamic at the moment of droplet transfer during
standard arc welding
-
0
+
The other adjustable process parameters correspond to the process parameters already
described:
-
2-step / 4-step / S2-step / S4-step
m/min (ipm)
For example: 2 - 25
(depending on wire speed and welding characteristic)
-
-10.0 - +10.0
short arc
uncorrected arc length
longer arc
-10.0 - +10.0
lower droplet detachment force
neutral droplet detachment force
higher droplet detachment force
harder, more stable arc
neutral arc
soft, low-spatter arc