TPS 400i LSC
Mains voltage (U
ADV /nc
Max. effective primary current (I
Max. primary current (I
Mains fuse protection
Mains voltage tolerance
Mains frequency
Cos phi (1)
Max. permitted mains impedance Z
Recommended earth-leakage circuit breaker
Welding current range (I
MIG/MAG
TIG
Rod electrode
Welding current at
U
1
Output voltage range according to standard characteristic (U
MIG/MAG
TIG
Rod electrode
Open circuit voltage (U
Degree of protection
Type of cooling
Overvoltage category
Pollution level according to IEC60664
EMC device class
Safety symbols
Dimensions (l x w x h)
Weight
Max. noise emission (LWA)
1)
2)
)
1
)
1max
)
2
10 min/40 °C (104 °F)
= 380 - 460 V
peak / U
0
Interface to a 230/400 V, 50 Hz public grid
A Class A equipment is not intended for use in residential locations where the elec-
trical power is provided by the public low-voltage supply system.
There can be potential difficulties in ensuring electromagnetic compatibility in those
locations, due to conducted as well as radiated radio-frequency disturbances.
3 x
)
1eff
1)
on PCC
max
r.m.s)
0
380 V
400 V
460 V
17.1 A
16.4 A
14.8 A
27.0 A
25.9 A
23.4 A
35 A slow-blow
+/-15%
50/60 Hz
0.99
92 mOhm
Type B
3 - 400 A
3 - 400 A
10 - 400 A
40%
60%
100%
400 A
360 A
320 A
)
2
14.2 - 34.0 V
10.1 - 26.0 V
20.4 - 36.0 V
84 V
IP 23
AF
III
A
S, CE
706 x 300 x 720 mm
27.8 x 11.8 x 28.4 in.
54.4 kg
119.9 lb.
77 dB (A)