MIG/MAG and CMT welding

Safety

MIG/MAG and
The "MIG/MAG and CMT welding" section comprises the following steps:
CMT welding –
-
overview
-
-
-
-
-
Switching on the
1
power source
2
A cooling unit connected to the system will begin to operate.
IMPORTANT! For optimum welding results, the manufacturer recommends performing an
R/L alignment when starting the device for the first time and when any changes are made
to the welding system.
More information about the R/L alignment can be found under "R/L alignment" in the "Pro-
cess parameters" section of the "Welding mode" chapter (page 107).
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described until you have thoroughly read and
understood the following documents:
-
these operating instructions
-
all the operating instructions for the system components, especially the safe-
ty rules
WARNING! An electric shock can be fatal. If the power source is connected to the
mains electricity supply during installation, there is a high risk of very serious in-
jury and damage. Before carrying out any work on the device make sure that:
-
the power source mains switch is in the "O" position
-
the power source is unplugged from the mains

Switching on the power source

Selecting the welding process and operating mode
Selecting the filler metal and shielding gas
Setting the welding and process parameters
Setting the shielding gas flow rate
MIG/MAG or CMT welding
NOTE! If using a cooling unit, follow the safety rules and note the operating con-
ditions in the cooling unit Operating Instructions.
Connect the mains cable
Move the mains switch to the "I" position
69