4-2. FUEL INJECTION SYSTEM

IGNITION COIL

• Turn the ignition switch OFF.
• Disconnect the ignition coil 2P connector.
• Check for loose or poor contact on the ignition coil
2P connector.
• Connect the ignition coil 2P connector.
• Turn the starter motor more than 10 seconds and
then check that the MIL light.
• Turn the ignition switch OFF.
• Disconnect the ignition coil 2P connector.
• Check for continuity between the ignition coil
connector terminal and ground.
Connection: Red (+) - Ground(-)
Standard: No continuity
• Check for resistance between the ignition coil
connector terminal and ground.
Standard:
0.6±0.05Ω
4-2-20