Precautions in Operation

General Information

This chapter contains maintenance operation
for the engine oil pump and gear oil replacement.
Specifications
Engine oil quantity
Overhaul: 2300 c.c.
Filter change: 1800 c.c.
Change: 2000 c.c.
Oil viscosity
Oil pump
Torque value
Torque value oil filter cover
Engine oil drain bolt
Troubleshooting
Low engine oil level
● Oil leaking
● Valve guide or seat worn out
● Piston ring worn out
● Camshaft worn out
● Camshaft main bearing worn out
Low oil pressure
● Low engine oil level
● Clogged in oil strainer, circuits or pipe, oil radiator gasket
● Oil pump damage
● Oil pressure valve, oil filter
Dirty oil
● No oil change in periodical
● Cylinder head gasket damage
● Piston ring worn out
● Camshaft worn out
● Camshaft main bearing worn out
PDF created with pdfFactory Pro trial version
SAE 10W-40
Items
Inner rotor clearance
Clearance between outer rotor and body
Clearance between rotor side and body
1.2 kgf-m
2.4 kgf-m
www.pdffactory.com

3.LUBRICATION SYSTEM

Standard (mm)
Limit (mm)
0.15
0.20
0.15~0.20
0.25
0.04~0.09
0.12