5.3
Maximum frequency
fh : Maximum frequency
Function
1) Programs the range of frequencies output by the inverter (maximum output values).
2) This frequency is used as the reference for acceleration/deceleration time.
Output frequency
(Hz)
80Hz
60Hz
● If is increased, adjust the upper limit frequency as necessary.
[Parameter setting]
Title
Maximum frequency
When =80Hz
When =60Hz
0
100%
Function
E-5
・This function determines the value
in line with the ratings of the motor
and load.
・Maximum frequency cannot be
adjusted during operation.To
adjust, first stop the inverter.
Frequency setting signal (%)
Adjustment range
30.0-500.0 (Hz)
E6581926
5
Default setting
80.0