Toshiba Tosvert VF-S15 Instruction Manual page 258

Industrial inverter (for 3-phase induction motors)
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

F
R
S2
CC
Forward
0
Reverse
HD
F
R
7
Power
Supply
Note 1) Set  =  (ST: standby) and  =  (terminal block) for 3 wire operation. Assign HD
Note 2) If the terminals are ON before turning on the power, terminal input is ignored when the power is
Note 3) When HD is OFF, F and R are ignored even when ON. R does not operate even if it's ON when
Note 4) During 3 wire operation, sending the jog run mode command stops operation.
Note 5) Be aware that DC braking continues even if a startup signal is input during DC braking.
Note 6) Only F and R maintain HD (operation hold). When using F or R in combination with other
[Parameter settings]
Terminal symbol
S2
Forward run
Reverse run
HD
Note 2)
(operation hold) to any input terminal at input terminal selection. When assigning the S2 terminal
as shown above, set  =  (HD: Operation hold).
turned ON. (Prevents sudden movements.) After turning the power ON, turn terminal input ON
again.
HD is ON. Likewise in this state, F does not operate even if it's ON. Turn F and R OFF and then
turn them ON.
functions, be aware that the other functions do not hold. For example, when F and SS1 are
assigned, F holds, but SS1 does not.
Title
 Input terminal selection 5 (S2)
Forward run (F) : Pressing forward run (F) rotates forward at
the specified frequency command value.
Reverse run (R) : Pressing reverse run (R) rotates in reverse
at the specified frequency command value.
HD (S2): Pressing HD (S2) decelerates and stops.
Note 3)
Function
Adjustment range
G-4
E6581926
Output
frequency
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Setting example
0-203
50: HD (Operation hold)