efesotomasyon.com -Toshiba inverter,drive,servo,plc
5.8
Maximum frequency
: Maximum frequency
• Function
1) Programs the range of frequencies output by the inverter (maximum output values).
2) This frequency is used as the reference for acceleration/deceleration time.
5
If is increased, adjust the upper limit frequency as necessary.
Parameter setting
Title
* Depends upon the setup menu settings. 50.0, 60.0, or 80.0 (Hz) is selected.
Output frequency
(Hz)
80Hz
60Hz
0
Function
Maximum frequency
When =80Hz
・This function determines the value
in line with the ratings of the motor
and load.
・Maximum frequency cannot be
When =60Hz
adjusted during operation.To
adjust, first stop the inverter.
100%
Frequency setting signal (%)
Adjustment range
30.0-400.0 (Hz)
E-14
E6581595
Default setting
∗