 Operation mode parameters
Communication
Title
No.
0300

0301

0302

0303

0304

0305

0307

11
0308

0309

0310

0311

0312

0314

*1: These are parameters set by setup menu. Default setting value is "jp". Refer to section 11.5.
*2: Default setting values vary depending on the capacity. Refer to section 11.4.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Minimum
setting unit
Function
Unit
Panel/Commun
ication
PWM carrier
kHz
0.1/0.1
frequency
Auto-restart
-
control selection
Regenerative
-
power ride-
through control
(Deceleration
stop)
Retry selection
Times
1/1
(number of times)
Dynamic braking
-
selection
Overvoltage limit
-
operation
(Deceleration stop
mode selection)
Supply voltage
-
correction
(output voltage
limitation)
Dynamic braking
0.1/0.1
resistance
Dynamic braking
kW
0.01/0.01
resistor capacity
Factory specific
-
coefficient 3A
Reverse-run
-
prohibition
Random mode
-
Factory specific
-
coefficient 3B
Adjustment range
2.0 -16.0
-
0: Disabled
1: At auto-restart after momentary
stop
2: At ST terminal off and on
3: 1+2
4: At start-up
-
0: Disabled
1: Regenerative power ride-through
control
2: Deceleration stop during power
failure
3: Synchronized acceleration /
deceleration (signal)
4: Synchronized acceleration /
deceleration (signal + power failure)
0: Disabled
1-10
-
0: Disabled
1: Enabled, Resistor overload
protection enabled
2: Enabled
3: Enabled, Resistor overload
protection enabled
(At ST terminal on)
4: Enabled (At ST terminal on)
-
0: Enabled
1: Disabled
2: Enabled (Quick deceleration
control)
3: Enabled (Dynamic quick
deceleration control)
-
0: Supply voltage uncorrected,
output voltage limited
1: Supply voltage corrected,
output voltage limited
2: Supply voltage uncorrected,
output voltage unlimited
3: Supply voltage corrected,
output voltage unlimited
1.0-1000
0.01-30.00
-
-
-
0: Forward/reverse run permitted
1: Reverse run prohibited
2: Forward run prohibited
-
0: Disabled
1: Random mode 1
2: Random mode 2
3: Random mode 3
-
-
K-10
E6581926
Default
User
Reference
setting
setting
12.0
6.18
0
5.9
0
6.19.2
0
6.19.3
0
6.19.4
2
6.19.5
3 *1
6.19.6
*2
6.19.4
*2
-
* 3
0
6.19.7
0
6.18
-
* 3