<Frequency setting mode selection>
[Parameter setting]
Title
Function
Frequency setting mode selection 1

[Programmed value]
:
Setting dial 1
:
Terminal VIA
:
Terminal VIB
:
Setting dial 2
RS485
:
communication
UP/DOWN from
:
external logic input
CANopen
:
communication
0: Setting dial 1(save even if power is off)
1: Terminal VIA
2: Terminal VIB
3: Setting dial 2(press in center to save)
4: RS485 communication
5: UP/DOWN from external logic input
6: CANopen communication
7: Communication option
8: Terminal VIC
9, 10: -
11: Pulse train input
12, 13: -
14: sro
Frequencies are set by rotating the setting dial on the inverter. Like the position
of notches in a volume knob, the frequency setting value at the position of the
notch is saved.
The frequency setting value is set by
 Refer to section 3.1.2
A frequency command is set by means of external analog signals.
(VIA terminal: 0 –10Vdc)
 Refer to section 3.1.2 and 7.3
A frequency command is set by means of external analog signals.
(VIB terminal: 0 - +10Vdc or -10 - +10Vdc)
 Refer to section 3.1.2 and 7.3
Frequencies are set by rotating the setting dial on the inverter. Press the center
of the setting dial to save the frequency setting value.
The frequency setting value is set by
 Refer to section 3.1.2
Frequencies are set by RS485 communication from an external device.
 Refer to section 6.38
Frequencies are set by up/down commands from a terminal.
 Refer to section 6.10.4
Frequencies are set by CANopen communication from an external device.
 Refer to "CANopen communication Instruction Manual E6581911".
F-13
Adjustment range
keys on an extension panel option.
keys on an extension panel option.
E6581926
Default setting
0
6