 Table of output terminal functions 3
Function
Code
No.
92
DATA1
Designated data output 1
93
DATA1N
Inversion of designated data output 1
94
DATA2
Designated data output 2
95
DATA2N
Inversion of designated data output 2
106
LLD
Light load output
107
LLDN
Inversion of light load output
108
HLD
Heavy load output
109
HLDN
Inversion of
120
LLS
Lower limit frequency stop
121
LLSN
Inversion of lower limit frequency stop
122
KEB
Power failure synchronized operation
123
KEBN
Inversion of power failure synchronized
operation
124
TVS
Traverse in progress
125
TVSN
Inversion of traverse in progress
126
TVSD
Traverse deceleration in progress
127
TVSDN
Inversion of traverse deceleration in
progress
128
LTA
Parts replacement alarm
129
LTAN
Inversion of parts replacement alarm
130
POT
Over-torque detection pre-alarm
131
POTN
Inversion of over-torque detection pre-alarm
132
FMOD
Frequency setting mode selection 1/2
133
FMODN
Inversion of frequency setting mode
selection 1/2
136
FLC
Panel / remote selection
137
FLCN
Inversion of panel / remote selection
138
FORCE
Forced continuous operation in progress
139
FORCEN
Inversion of forced continuous operation in
progress
140
FIRE
Specified frequency operation in progress
141
FIREN
Inversion of specified frequency operation in
progress
Function
ON: bit0 of FA50 is ON
OFF: bit0 of FA50 is OFF
Inversion of DATA1
ON: bit1 of FA50 is ON
OFF: bit1 of FA50 is OFF
Inversion of DATA2
ON: Less than heavy load torque (f335~f338)
OFF: heavy load torque (f335~f338) or more
Inversion of LLD
ON: Heavy load torque (f335~f338) or more
OFF: Less than heavy load torque (f335~f338)
heavy load output
Inversion of HLD
ON: Lower limit frequency continuous operation
OFF: Other than those above
Inversion of LLS
ON: Power failure synchronized operation
OFF: Other than those above
Inversion of KEB
ON: Traverse in progress
OFF: Other than those above
Inversion of TVS
ON: Traverse deceleration in progress
OFF: Other than those above
Inversion of TVSD
ON: Any one of cooling fan, control board capacitor, or main
OFF: Any one of cooling fan, control board capacitor, or main
Inversion of LTA
ON: Torque current is 70% of f616 setting value or more
OFF: Torque current is less than f616x70%-f619
Inversion of POT
ON: Select frequency setting mode selection 2 (f207)
OFF: Select frequency setting mode selection 1 (fmod)
Inversion of FMOD
ON: Operation command or panel
OFF: Other than those above
Inversion of FLC
ON: Forced continuous operation in progress
OFF: Other than those above
Inversion of FORCE
ON: Specified Frequency operation in progress
OFF: Other than those above
Inversion of FIRE
K-37
Action
circuit capacitor reaches parts replacement time
circuit capacitor does not reach parts replacement time
E6581926
Reference
6.38
6.21
6.13
6.19.2
6.40
6.29.15
6.29.10
5.8
6.2.1
11
6.30