Toshiba Tosvert VF-S15 Instruction Manual page 119

Industrial inverter (for 3-phase induction motors)
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

Output
frequency (Hz)
Set  (automatic acceleration/deceleration) to  or .
[Parameter setting]
Title

● When automatically setting acceleration/deceleration time, always change the acceleration/deceleration
time so that it conforms to the load. For inverters that require a fixed acceleration/deceleration time, use
the manual settings (, ).
6
● Setting acceleration/deceleration time (, ) in conformance with mean load allows optimum
setting that conforms to further changes in load.
● Use this parameter after actually connecting the motor.
● When the inverter is used with a load that fluctuates considerably, it may fail to adjust the acceleration or
deceleration time in time, and therefore may be tripped.
● Do not set  = when using a dynamic braking resistor (optional).
[Methods of setting automatic acceleration/deceleration]
Operation panel
● Assigning the fast stop command 2 (function number 122/ 123) to any logic input terminal, it can be
changed automatic deceleration by compulsion.
Example in case the acceleration
and deceleration time become short

0
Deceleration
Acceleration
time
time
Function
Automatic acceleration/deceleration
LED display
action


MODE


Example in case the acceleration
Output
and deceleration time become long
frequency (Hz)

0
Time
[sec]
Acceleration
time
Adjustment range
0: Disabled (manual setting)
1: Automatic
2: Automatic (only at acceleration)
Operation
Displays the output frequency.
(When standard monitor display selection  is set to 
[output frequency])
The first basic parameter "" (history function) is displayed.
Turn the setting dial to the right to change the parameter to .
Set values are displayed by pressing the center of the setting dial.
Turn the setting dial to the right to switch 1 or .
Press the center of the setting dial to save the changed set value.
 and the set value are displayed alternately.
F-8
E6581926
Time
[sec]
Deceleration
time
Default setting
0

Hide quick links: