4.5

EASY key function

psel : EASY key mode selection
f750 : EASY key function selection
f751 to f782 : Easy setting mode parameter 1 to 32
 Function
It is possible to switch between standard mode and easy setting mode using the EASY key. (default setting)
Up to 32 arbitrary parameters can be registered to easy setting mode.
The EASY key can select following four functions.
• Easy / Standard setting mode switching function
• Shortcut key function
• Local / Remote switching function
• Peak hold function
[Parameter setting]
Title
EASY key mode selection
psel
EASY key function selection
f750
 Easy / Standard setting mode switching function (f750=0): Default setting
It is possible to switch between standard mode and easy setting mode when you push the EASY key while the
inverter is stopping.
Standard setting mode is selected when the power is turned on at default setting.
The way parameters are read out and displayed varies according to the mode selected.
Easy setting mode
Allows pre-registration (easy setting mode parameters) of frequently changed parameters and reading of only
registered parameters (maximum of 32 types). Ten parameters are preliminary selected and can be changed as
occasion.
In the Easy setting mode, the EASY key lamp is lit.
Standard setting mode
All parameters are read out in standard setting mode.
Function
0: Standard setting mode at power on
1: Easy setting mode at power on
2: Easy setting mode only
0: Easy / standard setting mode switching function
1: Shortcut key
2: Local / remote key
3: Monitor peak / minimum hold trigger
D-15
Adjustment range
E6581926
4
Default setting
0
0