Notes on operation
 If no history information is stored, this parameter is skipped and the next parameter "aua" is displayed.
 head and end are added respectively to the first and last parameters in a history of changes.
Note: The following parameters are not displayed in this auh, even if they are the most recent changes.
fc (Operation frequency of operation panel),
au2 (Torque boost setting macro function),
set (Checking the region setting),
f737 (All key operation prohibition ) ,
f739 (Password verification)
6.1.2
Application easy setting (aua)
aua : Application easy setting
Application easy setting (aua):
Parameters necessary to your machine can be set easily using the application easy setting.
The parameters necessary to the machine is set to easy setting mode parameters 1-32 (f751-f782). Set the
parameters using the easy setting mode. (Refer to section 4.5.)
[Parameter setting]
Title
Function
Application easy setting
aua
auf (Guidance function),
au1 (Automatic acceleration/deceleration),
typ (Default setting),
f700 (Parameter protection selection) ,
f738 (Password setting (f700)) ,
Adjustment range
0:-
1: Initial easy setting
2: Conveyor
3: Material handling
4: Hoisting
5: Fan
6: Pump
7:Compressor
F-3
E6581926
6
Default setting
0