Toshiba Tosvert VF-S15 Instruction Manual page 259

Industrial inverter (for 3-phase induction motors)
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

 List of logic input terminal function settings
Parameter
programmed value
Positive
Negative
logic
logic
No function




Forward run command
Reverse run command




Standby
Reset command


 
 
Preset-speed command 1
 
 
Preset-speed command 2
Preset-speed command 3
 
 
 
 
Preset-speed command 4
Jog run mode
 
 
 
 
Emergency stop by external signal
DC braking command
 
 
 
 
2nd acceleration/deceleration
3rd acceleration/deceleration
 
 
 
 
2nd V/F control mode switching
2nd stall prevention level
 
 
 
 
PID control prohibition
External thermal error input
 
 
 
 
Forced local from communication
 
 
Operation hold (hold of 3-wire operation)
PID integral/differential clear
 
 
 
 
PID characteristics switching
Forced run operation
 
 
 
 
Fire speed operation
Acceleration/deceleration suspend signal
 
 
 
 
Power failure synchronized signal
My function-s trigger signal
 
 
 
 
Factory specific coefficient *1
*1: Factory specific coefficients are manufacturer setting menus. Do not change the value of these parameters.
*2: Active when  (frequency setting mode selection) =  (UP/DOWN from external logic input) is set.
The frequency setup range is from  to  (maximum frequency). The acceleration/deceleration time
relative to the set frequency is / while the acceleration/deceleration speed is not switched.
 Refer to section 11.6 for details about the input terminal function.
Parameter
programmed value
Function
Positive
logic
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 to 

 
 
G-5
Function
Negative
logic
Integrating wattmeter (kWh) display
 
clear
 
Trace back trigger signal
Light-load high-speed operation
 
prohibitive signal
 
Holding of RY-RC terminal output
Holding of OUT-NO terminal output
 
 
Frequency UP *2
 
Frequency DOWN *2
Clear frequency UP/DOWN *2
 
 
Coast stop command
Forward/reverse selection
 
 
Run/Stop command
Frequency reference command forced
 
switching
 
Frequency setting mode terminal block
Command mode terminal block
 
 
Parameter editing permission
Fast stop command 1
 
 
Fast stop command 2
Traverse permission signal
 
 
Low voltage operation
 
Forward deceleration
Forward stop
 
 
Reverse deceleration
Reverse stop
 
Factory specific coefficient *1
No.2 motor switching

 
Parameter editing prohibition
Parameter reading prohibition
 
E6581926
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents