2. After selecting the position of a figure you want to change, specify/confirm a
value with the control dial.
(In this example, 30.0Hz is specified.)
Functions of function keys
The functions keys allow you to select the position or decimal place
of each figure (operation frequency) you want to increment or
decrement with the control dial.
F1
: Selects the position of 1000 times of minimum setting unit.
: Selects the position of 100 times of minimum setting unit.
F2
: Selects the position of 10 times of minimum setting unit.
F3
: Selects the position of minimum setting unit (In this case, 0.1).
F4
When you confirm the value specified, the screen goes back to the top window of Top View Mode.
3
To change the frequency during operation
Press the control dial during operation to display the operation panel operation frequency menu and turn the control
dial to change the setting.

3.3.2 Using an EASY key function

The [F1] function key can be used as a substitute for the EASY key described in the manual E6581386 5.22. The
name of the function assigned to the [F1] key is displayed in the lower left corner of the window, and the [F1] key can
be used as the EASY key.
"Quick"
"Loc/Rem"
"Update"
* Shortcut key function (F750=1) cannot be used. Even if the
parameter is set so, the name of the function is not displayed
on the screen.
(1) Quick mode / standard setting mode switching function
<Standard Setting mode is selected at power on (parameter PSEL=0)>
• When power is turned on, "Quick" is displayed. ([F1] key is in OFF State)
In this case, top window of Parameter Setup Mode is ordinary one.
• If the [F1] key is pressed while "Quick" is displayed, it turns to highlighted "
In this case, the Quick mode window appears as the top window of Parameter Setup Mode.
<Quick mode is selected at power on (parameter PSEL=1)>
• When power is turned on, highlighted "
In this case, the Quick mode window appears as the top window of Parameter Setup Mode.
• If the [F1] key is pressed while "
In this case, top window of Parameter Setup Mode is ordinary one.
<Always Quick mode (parameter PSEL=2)>
• Highlighted "
The Quick mode window appears as the top window of Parameter Setup Mode.
* In this case, [F1] key is not active.
: Quick mode / standard setting mode switching
(F750=0)
: Local / Remote key (F750=2)
: Monitor peak / minimum hold trigger (F750=3)
Quick
Quick
" is displayed, it turns to normal "Quick". ([F1] key is in ON State)
Quick
" is displayed.
Output frequency
min=0.0
×1000
F1
FWD 60.0 Hz
Quick
Quick
Loc/Rem
Update
" is displayed. ([F1] key is in OFF State)
C-4
E6581429
Basic Parameters
FC
Panel frequency
0.0
Hz
30.0Hz
max=60.0
×100
×10
×1
F2
F3
F4
Top View Mode
STOP
0.0
Hz
Lng
---
Quick
". ([F1] key is in ON State)