14 Installation of Rail Assembly
1. Retrieve harness from end of rail.
Note: Harness has limited travel and can be damaged.
2. Attach harness to female connector on chassis.
3. Install rail and screws per exit device instructions.
Note: This view shows rim exit device version.

Operational Check

9
IMPORTANT: Be sure to test functions prior to closing door.
In all cases, perform the following checks:
1. Ensure that inside lever retracts latch.
• For units with cylinders, the following checks apply:
Insert key into cylinder and rotate:
a. There should be no friction against lock case or any other
obstructions. If friction or binding occurs, readjust cylinder to
eliminate issues.
b. The key should retract the latch and the key should rotate
freely.
• For units without a keypad, add card using LCT
software* and test.
• For units with a keypad, add pin and card using LCT software*
and test.
2. LED signaling:
• After using a valid credential, a green flash followed by three fast
amber flashes indicates a low power condition.
Check the battery voltage.
If the voltage is low, replace the batteries.
• If the lock loses power, it will flash rapid blue for approximately one
minute. Lock will default to programmed fail safe or fail secure.
After that, the lock will no longer be functional.
3. When you have completed the tests, close the door, ensuring latchbolt
and deadbolt fully extend into strike plate without binding.
*Refer to Network and Lock Configuration Tool user manual (WFMN1) for
information on how to configure and program locks.
1-800-810-WIRE • www.sargentlock.com • A8034G