Operational Check

8
For devices with cylinders:
1. Insert key into cylinder and rotate:
The key will retract the latch.
The key should rotate freely.
2. Ensure inside lever retracts latch.
3. Close door: Ensure latch is fully extended and
does not bind.
Note: Once electrical wiring has been success-
fully completed according to proper application,
complete the following step:
1. Turn power ON.
2. Verify LED located on reader is ON
(Red or Green depending on reader
configuration (See reader
LED Configuration).
3. Present proximity credential and verify
LED and sounder activity.
4. Verify valid card read at EAC panel.
5. Verify system operation functions;
i.e., when Prox credential is presented
to reader that the door unlocks.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
Harmony Series H2 Cylindrical Lock
Feature
12 or 24VDC solenoid
lock voltage adjustable
Operates as Fail Safe or
Fail Secure
"Learn" mode allows
testing of specific cards
without programming at
the panel level
Card reader data inte-
grity is validated at test
unit
Works with SE LP10
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
Displays measured end-
of-line resistor values
(if applicable)
18
A8028E • 800-810-WIRE (9473) • www.sargentlock.com
WT1
WT2
X
X
X
X
X
X
X
X
X
X
X
X

Advertisement

loading

This manual is also suitable for:

Assa abloy h2