Sargent PASSPORT 1000 Exit Device Installation Instructions Manual page 26

Table of Contents

Advertisement

10 Mounting Plate Assembly
1. On the inside of the door, position the mounting plate over the indicated holes.
2. Feed reader and DPS cables through central opening on mounting plate (Fig. 10).
3. Route ground ring terminal from lock body through bottom of mounting plate and
attach to bottom right corner using (1) #8-32 x 1-7/8" flat head machine screw.
4. Insert other three #8-32 x 1-7/8" flat head machine screws and tighten, fastening
the outside escutcheon to the door (Fig. 10).
: If the following step is skipped, the product
IMPORTANT
will not be UL-compliant:
5. Attach two (2) #8 x 3/8" flat head wood screws for
wood doors or (2) #8-32 x 3/8" flat head machine
screws for metal doors (Fig. 10).
1-800-810-WIRE • www.sargentlock.com • A8034G
Passport 1000 P1 Exit Device
Fig. 10
26
Cat 5e cable
from hinge

Advertisement

Table of Contents
loading