Download Print this page

Mechanical Operational Check; Electrical Operational Check - Sargent ASSA ABLOY Profile Series Installation Instructions Manual

Advertisement

Profile Series v.N1 Cylindrical Lock

Mechanical Operational Check

8
For devices with cylinders:
1. Insert key into cylinder and rotate.
2. Ensure that the key retracts the latch.
3. Ensure that the key rotates freely.
4. Ensure that the inside lever retracts latch.

Electrical Operational Check

9
1. Configure the lock to display the red LED when locked. The red LED should be present, if powered.
2. I f the red LED is present, the door should be locked. If that is not the case, check the fail safe / fail
secure configuration on the controller.
3. When wired to the interface module, LED 3 on the interface module should flash rapid and green.
4. I f a short circuit is supplied across LOCK terminals on the appropriate integration connector on the
interface module (TS4, TS5, TS6, TS7), the door should unlock.
14
800-810-WIRE (9473) • www.sargentlock.com • A0806B
Hardwiring Made Easy™
As part of their promise to provide
innovative, fast and effective high
security solutions to their customers,
ASSA ABLOY Group companies offer
ElectroLynx
, a universal quick-connect
®
system that simplifies the electrification of
the door opening.
ElectroLynx
is a registered trademark of
®
ASSA ABLOY Inc.

Advertisement