8
1. Insert key into cylinder and rotate:
The key will retract the latch.
The key should rotate freely.
2. Ensure inside lever retracts latch.
3. Close door: Ensure latch is fully extended and does not bind.
Note: Once electrical wiring has been successfully
completed according to proper application, perform
the following:
1. Ensure lock is interfaced with Wiegand Test Unit
to verify installation & wiring up to the point of hinge
(frame side).
2. Turn power ON.
3. Wait for LED to turn RED and then present compatible
credential and verify LED and sounder activity.
4. Verify valid card read on Wiegand Test Unit or at the
EAC panel.
5. Verify system operation functions; i.e., when a valid
credential is presented to reader, the door should unlock.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field*. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities**.
Wiegand Test Unit - WT1
Wiegand Test Unit - WT2
20
SN200/210 Cylindrical Lock
Feature
12 or 24VDC solenoid lock
voltage adjustable
Operates as Fail Safe or Fail
Secure
"Learn" mode allows testing
of specific cards without pro-
gramming at panel level
Card reader data integrity is
validated at test unit
Displays detailed Wiegand
data, including hexadecimal
string and total bits received
Displays measured end-of-line
resistor values (if applicable)
Displays key-press data from
keypad readers
*For directions on use, see operating instructions provided with unit.
**SN200/210 keypad version works only with WT2
WT2 unit with 1.03 firmware or later is required
A8282A • 800-810-WIRE (9473) • www.sargentlock.com