Nextscale Nx360 M5 Water-Cooled - Lenovo NeXtScale nx360 M5 Installation And Service Manual

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
– Lenovo Support website
– Latest level of DSA
• 406-903-000 : IANet:Interrupts Test Failed
A failure was detected during the Interrupt test.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log. If the
ethernet device is sharing interrupts, if possible modify the interrupt assignments using F1 Setup
to assign a unique interrupt to the device.
4. Rerun the test.
5. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
– Lenovo Support website
– Latest level of DSA
• 406-904-000 : IANet:Loopback Test Failed
A failure was detected during the Loopback test.
Recoverable
No
Severity
Error
746
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide