Lenovo NeXtScale nx360 M5 Installation And Service Manual page 481

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed and following the memory population chart in the system
publication. One of the DIMMs :
• 806f070d-0401ffff : Rebuild in progress for Array in system [ComputerSystemElementName].
(Computer HDD0)
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
May also be shown as 806f070d0401ffff or 0x806f070d0401ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
• 806f070d-0402ffff : Rebuild in progress for Array in system [ComputerSystemElementName].
(Computer HDD1)
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
May also be shown as 806f070d0402ffff or 0x806f070d0402ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
467

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n1200

Table of Contents