Lenovo NeXtScale nx360 M5 Installation And Service Manual page 65

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

The IMM account password (1 of 12 accounts). The default value is PASSW0RD (with a zero
0 not an O).
Note: If you do not specify any of these parameters, ASU will use the default values. When the
default values are used and ASU is unable to access the IMM using the online authenticated
LAN access method, ASU will automatically use the unauthenticated KCS access method.
The following commands are examples of using the userid and password default values and not
using the default values:
Examples that do not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
--user <imm_user_id> --password <imm_password>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> --user <imm_user_id>
--password <imm_password>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
--user <imm_user_id> --password <imm_password>
Examples that do use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Online KCS access (unauthenticated and user restricted): You do not need to specify a value for
access_method when you use this access method.
The KCS access method uses the IPMI/KCS interface. This method requires that the IPMI driver
be installed. Some operating systems have the IPMI driver installed by default. ASU provides the
corresponding mapping layer. To download the Advanced Settings Utility Users Guide,
complete the following steps:
Note: Changes are made periodically to the Lenovo website. The actual procedure might vary
slightly from what is described in this document.
1. Go to http://www.lenovo.com/support.
2. Click on the Downloads tab at the top of the panel.
3. Under ToolsCenter, select View ToolsCenter downloads.
4. Select Advanced Settings Utility (ASU).
5. Scroll down and click on the link and download the ASU version for your operating system.
Scroll down and look under Online Help to download the Advanced Settings Utility Users
Guide.
• The following commands are examples of using the userid and password default values and not
using the default values:
Examples that do not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Bootable media: Remote LAN access, type the command:
Note: When using the remote LAN access method to access IMM using the LAN from a client,
the host and the imm_external_ip address are required parameters.
host <imm_external_ip> [user <imm_user_id>][password <imm_password>]
Where:
imm_external_ip
The external IMM LAN IP address. There is no default value. This parameter is required.
imm_user_id
.
Chapter 3
Configuration information and instructions
51