Nextscale Nx360 M5 Water-Cooled - Lenovo NeXtScale nx360 M5 Installation And Service Manual

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
• 816f000d-0407ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Comput HDD6 Pres)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0407ffff or 0x816f000d0407ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
• 816f000d-0408ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Comput HDD7 Pres)
538
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n1200

Table of Contents