3. If a fan has failed, complete the action for a fan failure.
4. Replace DIMM n. (n = DIMM number)
• 806f0a0c-2010ffff : An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c2010ffff or 0x806f0a0c2010ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air
baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2. Make sure that ambient temperature is within the specifications.
3. If a fan has failed, complete the action for a fan failure.
4. Replace DIMM n. (n = DIMM number)
• 806f0a13-0301ffff : A Fatal Bus Error has occurred on bus [SensorElementName]. (CPU 1 PECI)
This message is for the use case when an implementation has detected a Bus Fatal Error.
May also be shown as 806f0a130301ffff or 0x806f0a130301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0244
User Response
1. (Trained technician only)Reseat the microprocessor, and then restart the server.
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
501