7. If problem stays with the original DIMM connector, re-inspect DIMM connector for foreign
material and remove, if found. If connector is damaged, replace system board
• S.68005 [S.68005]
Explanation: An error has been detected by the the IIO core logic on Bus %. The Global Fatal Error Status
register contains %. The Global Non-Fatal Error Status register contains %. Please check error logs for
the presence of additional downstream device error data. Critical IOH-PCI Error
Severity
Error
User Response
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device and resolve that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the
system or adapter that applies to this error.
3. Replace the I/O device or PCIe adapter
4. (Trained technician only)Replace the system board reported in the error.
• S.680B8 [S.680B8]
Explanation: Internal QPI Link Failure Detected. Internal QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this error.
2. Inspect the processor socket for foreign debris or damage. If debris is found, remove the debris.
3. (Trained technician only)If error recurs, or socket damage is found, replace the system board
4. (Trained Service Technician Only) Replace the processor.
• S.680B9 [S.680B9]
Explanation: External QPI Link Failure Detected. External QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this error.
2. Inspect the processor socket for foreign debris or damage. If debris is found, remove the debris.
3. (Trained technician only)If error recurs, or socket damage is found, replace the system board
• W.11004 [W.11004]
Explanation: A processor within the system has failed the BIST. Processor Self Test Failure Detected
Severity
Error
User Response
Complete the following steps:
706
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide