Appendix A. Integrated Management Module 2.1 (IMM2.1)
error messages
This section details the Integrated Management Module 2.1 (IMM2.1) error messages.
When a hardware event is detected by the Integrated Management Module 2.1 (IMM2.1) on the server, the
Integrated Management Module 2.1 (IMM2.1) logs that event in the system-event log in the server.
For each event code, the following fields are displayed:
Event identifier
A hexadecimal identifier that uniquely identifies an event or class of events. In this documentation, the
event identifiers are prefixed with 0x and followed by eight characters.
Event description
The logged message string that appears for an event. When the event string is displayed in the event
log, information such as a specific component is displayed. In this documentation, that additional
information appears as variables, such as [arg1] or [arg2].
Explanation
Provides additional information to explain why the event occurred.
Severity
An indication of the level of concern for the condition. In the system-event log, severity is abbreviated to
the first character. The following severities can be displayed.
Info:
The event was recorded for audit purposes, usually a user action or a change of states that is
normal behavior.
Warning:
The event is not as severe as an error, but if possible, the condition should be corrected before it
becomes an error. It might also be a condition that requires additional monitoring or maintenance.
Error:
The event is a failure or critical condition that impairs service or an expected function.
Alert Category
Similar events are grouped together in categories. The alert category is in the following format:
severity - device
severity is one of the following severity levels:
• Critical: A key component in the server is no longer functioning.
• Warning: The event might progress to a critical level.
• System: The event is the result of a system error or a configuration change.
device is the specific device in the server that caused the event to be generated.
Serviceable
Specifies whether user action is required to correct the problem.