Lenovo NeXtScale nx360 M5 Installation And Service Manual page 393

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server each
time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive
backplane (n = hard disk drive number)
• 806f0223-2101ffff : Powering off system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Poweroff by Watchdog has
occurred.
May also be shown as 806f02232101ffff or 0x806f02232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0372
User Response
No action; information only.
• 806f030c-2001ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2001ffff or 0x806f030c2001ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
379

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n1200

Table of Contents