Lenovo NeXtScale nx360 M5 Installation And Service Manual page 705

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
• 816f0a13-0301ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error. (CPU 1 PECI)
This message is for the use case when an implementation has detected that a system has recovered from
a Bus Fatal Error.
May also be shown as 816f0a130301ffff or 0x816f0a130301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0245
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Replacing the system board). (n = microprocessor number)
• 816f0a13-0302ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error. (CPU 2 PECI)
This message is for the use case when an implementation has detected that a system has recovered from
a Bus Fatal Error.
May also be shown as 816f0a130302ffff or 0x816f0a130302ffff
Severity
Info
Serviceable
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
691

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n1200

Table of Contents