Prefix: PLAT ID: 0522
User Response
None ME Flash Error :
• 80070301-0301ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less
severe state. (CPU 1 OverTemp)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable from less severe.
May also be shown as 800703010301ffff or 0x800703010301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0524
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear
of the server), that the air baffle is in place and correctly installed, and that the server cover is
installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Make sure that the heat sink for microprocessor n.
4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
CPU1 VR OverTemp :
• 80070301-0302ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less
severe state. (CPU 2 OverTemp)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable from less severe.
May also be shown as 800703010302ffff or 0x800703010302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0