Lenovo NeXtScale nx360 M5 Installation And Service Manual page 717

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
2. Update the UEFI image.
3. Replace the system board.
• S.3070007 [S.3070007]
Explanation: A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
2. Update the UEFI image.
3. Replace the system board.
• S.3108007 [S.3108007]
Explanation: ] The default system settings have been restored. System Configuration Restored to
Defaults
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
• S.3818004 [S.3818004]
Explanation: The CRTM flash driver could not successfully flash the staging area. A failure occurred.
CRTM Update Failed
Severity
Error
User Response
Complete the following steps:
1. Continue booting the sytem. If the system does not reset, manually reset the system.
2. If the error is not reported on the subsequent boot, no additional recovery action is required.
3. If the error persists, continue booting system and update the UEFI image.
4. (Trained service technician only) Replace the system board.
• S.3818007 [S.3818007]
Explanation: The firmware image capsules for both flash banks could not be verified. CRTM image
capsule could not be verified
Severity
Error
Appendix B. UEFI/POST diagnostic codes
703