Lenovo NeXtScale nx360 M5 Installation And Service Manual page 557

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
• 816f000d-0410ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (1U Stg HDD7 Pres)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0410ffff or 0x816f000d0410ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
SDHV Drive 1 :
• 816f000d-0411ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (SDHV Drive 2)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0411ffff or 0x816f000d0411ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
543