Lenovo NeXtScale nx360 M5 Installation And Service Manual page 549

Water-cooled technology tray; enclosure
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

Serviceable
No
Automatically notify support
No
Alert Category
System - Power On
SNMP Trap ID
24
CIM Information
Prefix: PLAT ID: 0107
User Response
No action; information only.
• 816f000d-0401ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Comput HDD0 Pres)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0401ffff or 0x816f000d0401ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
• 816f000d-0402ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Comput HDD1 Pres)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0402ffff or 0x816f000d0402ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
535

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n1200

Table of Contents