• 405-900-000 : BRCM:TestControlRegisters Test Failed
A failure was detected while testing internal MAC registers
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
– Lenovo Support website
– Latest level of DSA
• 405-901-000 : BRCM:TestMIIRegisters Test Failed
A failure was detected while testing internal PHY registers.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
– Lenovo Support website
– Latest level of DSA
• 405-902-000 : BRCM:TestEEPROM Test Failed
A failure was detected while testing non-volatile RAM.
Recoverable
No
720