4. Replace the hard disk drive.
• 816f000d-041bffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (SDHV Drive 12)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d041bffff or 0x816f000d041bffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
• 816f000d-041cffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (SDHV Drive 13)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d041cffff or 0x816f000d041cffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.