10.8

Ratio Conversion

An input signal multiplied with the set ratio (x/y) is output from the multi function counter block.
Ratio conversion enables the following controls.
• An encoder output of the motor at the unwinding part is input to the programmable controller to control the motor speed of
lines with distribution output.
• The motor speed of multiple lines, for example, a printer, can be controlled.
The ratio (x/y) used in ratio conversion must be "y ≥ x" when a signal multiplied by x/y is output to an input signal. Conversions
with the ratio exceeding one time cannot be performed.
The following describes a link and parameter example of a ratio conversion. With the example setting, when a 1ms input
signal is output for 1ms after multiplied with 3/10. Note that this link example is for when a 32-bit unsigned multi function
counter block is used.
ON
Input signal
OFF
ON
Output signal
OFF
10 BLOCK LINK EXAMPLES
196
10.8 Ratio Conversion
Rolling out
1ms
Ratio conversion
1ms
Printing machine
Printing
3
10
Rolling up