Mitsubishi Electric MELSEC-L Series LD40PD01 User Manual page 181

Flexible high-speed i/o control module
Table of Contents

Advertisement

■Multi function counter block detail window
Block
Variable name
Input 0
Input_Signal_Event
Detector Select
Detector Select
Counter_Timer_0
Count Enable
Count Mode
Upper Limit
Lower Limit
Clock
Add Mode
Add Value
STOP → PRESET
PRESET → STOP
Preset Value
Compare_0
Condition
Compare Mode A
Compare Value A
Set/Reset_0
Output
*1 Output ON time = Clock cycle setting × (Compare value - Preset value + 1)
*2 In the addition mode, the output ON time calculated from the following is applied.
Output ON time = (Clock cycle setting × (Compare value - Preset value + 1) ÷ Addition value
The items other than the above need not to be set.
Setting value
User Setting (ON only in A: High)
User Setting (ON only in A: Rise)
ON
Linear
4294967295
0
1ms
OFF
0
ON
OFF
1
Coincidence
=
100
Description
Set this parameter to detect the phase A input signal.
Set this parameter to "ON".
Set this parameter according to the control.
Set this parameter according to the control.
Set this parameter according to the control.
Set this parameter according to the control.
Set this parameter according to the control.
Set this parameter to "ON", to perform a preset when
a stop event occurs.
Set this parameter to "OFF".
Set this parameter according to the control.
Set this parameter to "Coincidence".
Set this parameter to "=".
Set this parameter according to the control.
10 BLOCK LINK EXAMPLES
10.2 One-shot Timer
10
*1
*2
*1
*1
179