Linking blocks
Link blocks so that an output terminal of the left block in the window is handled as a start point and the input terminal of the
right block in the window is handled as an end point.
The following describes how to link blocks.
1.
Click the terminal to be a start point.
The outer frame of the selected terminal is highlighted.
2.
Click the terminal to be an end point.
The start point and end point are automatically linked.
Event terminals of a multi function counter block can be linked to Event terminals of another multi function
counter block arranged in the same section.
Handle an Event terminal at the output side (right side of a multi function counter block) as a start point and an
Event terminal at the input side (left side of a multi function counter block) as an end point, and link these
terminals.
8 FUNCTIONS OF THE CONFIGURATION TOOL