Monitor
The following table shows the monitors of the counter timer block.
Variable name
Data type
Count Value
Word
Latch Value
Word
Overflow
Word
Underflow
Word
*1 Even when no "User Address" is assigned, an overflow and an underflow are detected and the multi function counter block  overflow
error (error code: 100H) and the multi function counter block  underflow error (error code: 101H) occur. These errors are detected
only when the linear counter mode is set for 32-bit counter timer blocks.
The following table shows "User Address" used for the monitors.
Variable name
Data type
User Address
Word
Description
A count value is stored in the buffer memory area specified with "User Address".
A latched count value is stored in the buffer memory area specified with "User Address".
When an overflow is detected, 1 is stored in the buffer memory address specified with "User Address".
When an underflow is detected, 1 is stored in the buffer memory address specified with "User Address".
Linkable block
Valid range
1000 to 1099
Description
Only even addresses can be assigned to monitors of
two words (32 bits).
9 CREATING A HARDWARE LOGIC
9.2 Multi Function Counter Block
9
*1
*1
151