Operation
The following shows operation where a count value is compared with the setting value of each step.
Controlled by the flexible high-speed I/O control module
UP terminal
Cam switch output
terminal
Count value
Step No.
No.
Description
(1)
The count value is increased by one every time the UP terminal turns to High.
(2)
When the count value reaches the setting value of the step No. 0, an external output is inversed.
Also, every time the count value reaches each setting value of the step No. 1 or later, an external output is inversed.
10 BLOCK LINK EXAMPLES
186
10.4 Cam Switch
(1)
(2)
High
Low
High
Low
0
1 ・ ・ ・ 999
1000 ・ ・ 1999
0
2000 ・ ・ 2999
3000 ・ ・ 3999
4000 ・ ・ 4999
1
2
3
4
5000 ・ ・ 5999
6000 ・ ・ 6999 7000 ・ ・ ・