Mitsubishi Electric MELSEC-L Series LD40PD01 User Manual page 205

Flexible high-speed i/o control module
Table of Contents

Advertisement

Operation
The following shows operation of pulse measurement.
Controlled by the flexible high-speed I/O control module
Count value
0
Latch value
0
(1)
ON
Input signal
OFF
High
RUN terminal
Low
High
Latch terminal
Low
High
STOP terminal
Low
No.
Description
(1)
When the input signal is turned on, the RUN terminal turns to High and counting per clock cycle starts.
(2)
When the input signal is turned off, the following two operations are simultaneously performed.
• The Latch terminal turns to High and the current count value is latched.
• The STOP terminal turns to High, counting per clock cycle stops and preset is performed.
10
10
(2)
10 BLOCK LINK EXAMPLES
10.9 Pulse Measurement
10
203