Link combination
An input terminal and output terminal in the same color can be linked among the internal blocks. Input terminals or output
terminals cannot be linked each other.
The following table lists the combinations.
Output side
Block name
Input terminal
Latch input terminal
Event input terminal
Input signal event detection block
Latch event detection block
Counter timer block
Comparison block
Cam switch block
Set/reset block
*1 The terminals are linked by default. The links cannot be deleted.
*2 The terminals can be linked when a 16-bit multi function counter block is used. They cannot be linked when a 32-bit multi function
counter block is used.
If multiple output terminals are linked to one input terminal, OR processing is executed on all input signals. If one output
terminal is linked to multiple input terminals, the same signals are output for all the input terminals.
Input side
Terminal name
Block name
Input
Input signal event detection block
Latch
Latch event detection block
Event
Counter timer block
Output
Counter timer block
Set/reset block
Output terminal
Event output terminal
Output
Counter timer block
Count Value
Comparison block
Cam switch block
Output
Set/reset block
Event output terminal
Output
Cam switch output terminal
Output
Output terminal
Color
Terminal name
*1
Input
Coral
*1
Input
Pale orange
RUN
Butterfly yellow
STOP
UP
DOWN
PRESET
Latch
RUN
Hop green
STOP
UP
DOWN
PRESET
Set
Reset
Output
*2
Event
*1
Latch
Celadon
*1
Input
Cyan blue
*1
Input
Set
Vermeer
Reset
Event
*1
Cam Output
Columbine blue
Output
Lilac
9 CREATING A HARDWARE LOGIC
9.2 Multi Function Counter Block
9
131