Mitsubishi Electric MELSEC-L Series LD40PD01 User Manual page 42

Flexible high-speed i/o control module
Table of Contents

Advertisement

■Example of noise reduction measures taken to shielded cables
(1)
Remove the jacket of each shielded cable.
(2)
Take out a shield from a shielded cable and solder it on the FG wire.
(3)
Connect a shield of each shielded cable with a conductive tape.
(4)
Cover a connector pin with a heat-shrinkable insulation tube to protect signal wires. If signal wires are bared, the module may be affected by static
electricity and malfunction.
(5)
Cover the signal wires with an insulating tape.
■Assembling the A6CON1
(1)
Cover the cables on which a conductive tape has been applied with a heat-shrinkable tube.
6 INSTALLATION AND EXTERNAL WIRING
40
6.2 External Wiring
(4)
(1)
(1), (3)
(2)
(5)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents